There are two rules to box mapping, and if you understand them, it
is not a problem to remap:
1) If you connect a box while MIO Console is running, it will be mapped to its own
serial number in the console (if it exists) or it will get a new tab.
2) If a box is already in the console or a file, the data will be mapped to that box.
So, if you have 4 boxes (a, b, c, and d) and you have a file for (a, b, c) and you
need to swap d for b, the process is as follows:
1) Disconnect all MIOs from computer
2) Open File
3) If (d) is in the file, forget that offline tab
4) Save updated console to new file
5) QUIT MIO CONSOLE
7) Connect boxes (a, d, c) to computer (you cannot have b connected if you want to
map its data)
8) Launch MIO Console with new file
If the data for d is in the file, or if b is connected to the computer then you will
not be able to map.
The forging applies to any combination.
The point is that you don’t forget the tab of the box you want to map FROM. You only
forget the tab of the box you want to map TO.
Thanks BJ